GREEN-LINE GEO 120-3000 RG

Ready-to-install reverse osmosis system mounted on an aluminium frame. Our GREEN-LINE RG reverse osmosis units are characterised by their use of PLC control system with display and logging of the operating data, analogue measuring sensor with adjustable threshold values, PROFINET interface. Optional: Enclosure with door, frequency converter to ensure minimum power consumption and maximum permeate quality, initial permeate recirculation, residual hardness monitoring and other components.
Permeate capacity (l/h) |
120 | 200 | 400 |
Salt rejection rate (%) |
> 97 |
||
Yield (%) |
75 - 80 |
||
Feed water |
Softened tap water |
||
Inlet pressure (bar) |
2 - 4 |
||
Feed water |
DN 20 |
||
Permeate/concentrate |
DN 15 | ||
Electrical connection (V/Hz) |
230/50 – 370 W | ||
Width x Depth x Height (mm) |
700 x 600 x 1800 |
||
Operating temperature (°C) |
5 - 35 | ||
Ambient temperature (°C) |
5 - 40 | ||
Item No. |
320010 |
320011 |
320012 |
Model: GREEN-LINE |
120 RG |
200 RG |
400 RG |
Permeate capacity (l/h) |
800 | 1200 | 1500 | 2000 | 2500 | 3000 |
Salt rejection rate (%) |
> 97 |
|||||
Yield (%) |
75 - 80 |
|||||
Feed water |
Softened tap water | |||||
Inlet pressure (bar) |
2 - 4 |
|||||
Feed water |
DN 25 |
DN 32 | ||||
Permeate/concentrate |
DN 20 | DN 25 | ||||
Electrical connection (V/Hz) |
400/50 - 1,5 kW | 400/50 - 2,2 kW | ||||
Width x Depth x Height (mm) approx. |
1150 x 700 x 1800 |
1150 x 790 x 1800 | ||||
Operating temperature (°C |
5 - 35 | |||||
Ambient temperature (°C) |
5 - 40 | |||||
Item No. |
320013 |
320014 |
320015 |
320018 | 320019 | 320020 |
Model: GREEN-LINE |
800 RG |
1200 RG |
1500 RG |
2000 RG |
2500 RG |
3000 RG |